Genesis CD–15G and CD–25G Installation & Operations Manual
2C. Electrical
Refer to the units specification label and local
electrical codes for information on proper electrical
connection.
120V Models
Main power circuit: Unit is supplied with a
standard power cord. Plug cord into standard
120Vgrounded,goundingtypereceptacleonly.
230V Models
Main power circuit: 230V models are supplied
with an IEC 6032 C-14 Type power receptacle.
Apowercord,havingatleasta10AMPrating,with
a IEC 60320 C-13 Type plug and a country specific
plugisrequiredtopowergenerator.
2D. Plumbing
Ozonegasisintroducedtothecirculationline
usingaventuriinjector.Suctiondevelopedbythe
venturi allows the generator to operate safely under
vacuum. See installation manual for MX-601-XX
for proper venturi installation.
2D-1. Ozone Gas Line
1.Connectozonetubingtogeneratoroutletfitting.
(3/8"stainlesssteelcompressionfitting.)
2.Connectoppositeendofozonetubingtoinjector
suctionport.(Suctionportfitting:3/8"stainless
steel compression fitting.) See Figure 4.
NOTE: The ozone gas supply line must be
made of Teflon or stainless steel and have a
back flow prevention device (such as a check
valve) installed between the ozone generator
cabinet and the point of injection to prevent
water from backing up into the generator
system. An ozone supply check valve is
included with the MX–601–XX system.
Figure 4: Plumbing Schematic - Example of Swimming Pool Application
Figure 3: Country Specific Plug
(Australia shown for reference only)